The fully symmetrical optical system measures sample and reference simultaneously for ultimate accuracy, precision and baseline flatness. Long term stability is at least ten times better than single beam systems. Coated optics for long life.
Variable Optical Bandwidth
The CE 9500 offers variable optical bandwidth from 0.5mm to 4mm. This range covers all the more exacting applications where either high optical resolution or maximum energy throughput is required.
Method Operation and Storage
Up to 100 sets of instrument parameters, including concentration curves may be stored, security code protected. When recalled, instrument parameters are automatically set, avoiding errors.
Alpha Numeric Entry and Assay Program
A full Alpha Numeric facility is provided for formula entry and documentation for GLP. Assay formula entry with Assay Program is rapid and calculations using many wavelengths may be made at high speed with fully documented results.
Software Enhancement By E-SEF
E-SEF - Encoded Software Enhancement Facility - allows software modules to be enabled using encoded numbers provided by telephone, fax or E-mail. Software requirements may be tailored, at any time, as required.
Data Storage and Protection
Data, including 100 spectra, concentration curves , kinetics and time course plots may be stored in safe memory, security code protected against tamper or deletion using a four digit password.
Reprocessing
Scans, time course plots, and reaction curves may all be reprocessed to any required format on the display screen and then plotted on the integral or an external printer.
Photomultiplier Detector
A high performance end window photomultiplier is used in all instruments for best possible accuracy and optimum performance in narrow bandwidth, or energy limited applications, eg turbid sample measurement.
Performance Validation
Software and certified standards enable wavelength accuracy, Absorbance accuracy, bandwidth etc. to be validated. A timed and dated report includes the serial number of the instrument.
Powerful Quantification
Many quantitative methods are available including band area computation with background correction, differencing and stripping of spectra, wine and colour assays, mathematical calculations between several wavelengths, protein and DNA assays.
Assay Program
Assay formulae requiring measurements at up to 10 wavelengths may be entered rapidly. Programming for computation is automatic at entry without user intervention. Automatic sequences may be set for multi-sample assays and may be stored as methods.
Curve and Line Fitting
A straight line, quadratic or cubic concentration curve may be fitted to up to 30 standards, with or without an intercept at the origin. Standards may be deleted and replaced and a new curve fitted.
Reaction Kinetics
Single cell kinetic measurements are possible with plots and data displayed on screen. Data may be reprocessed, regression analysis applied and curves stored, security code protected against tamper or deletion.
Multi-Cell Reaction Kinetics
Up to four or six cells are automatically measured with all reaction curves displayed on screen. Each curve may be selected for processing with the results of regression analysis printed.
Multi Wavelength and Bio Assays
Assays are provided using either two or three wavelengths. A wine colour assay is provided. Assays for Warburg and Christian, Lowry, Bradford, Biuret and BCA methods are also available.
Band Area and Height Computation
Band areas with correction for sloping background absorption are readily quantified, with all details and construction displayed. Band areas may also be computed for derivative spectra to facilitate difficult quantification.
Cell Program
Using the various cell changers, measurements may be made on up to 4, 6 or 8 cells at a single wavelength with cycle time and number of cycles entered by the operator. A cell and wavelength program may be combined.
Wavelength Program
Measurements may be programmed for 10 different operator selected wavelengths with the cycle time and number of cycles selected by the operator. A wavelength and cell program may be combined.
Scanning
Double Beam Wavelength Scans
Scans at up to 4000nm/min are presented on screen or printed with all peaks annotated with wavelength and Absorbance. Tables are also presented listing all peaks and troughs with values.
Display Scrolling
Use of the display scrolling facility enhances the effective screen size and enables spectra and data up to 550mm wide, 6 screen widths, to be viewed. The last eight scans are automatically retained for recall by entering their scan sequence number and may be reprocessed, overlayed or transferred to protected memory for future recall.
Overlayed Spectral Scans
Up to six scans, including stored scans, may be overlayed, with or without offsets for convenient comparisons or further manipulation.
Difference Spectra
New wavelength scans or scans from store may be presented on screen and the difference spectra produced. The scans may be normalised enabling spectral stripping to reveal impurities or additives.
Derivative Spectra
Derivative spectra, up to sixth are readily produced, with selectable smoothing, either alone or superimposed on the fundamental, with or without an offset. Scaling is automatic with all peaks and troughs quantified.
Scan Storage
Up to 100 spectra may be stored in 10 safe memory banks for future recall. Each spectrum is automatically allocated a recall number, when stored, and may be security code protected against tamper or deletion.
Programmed Scans
Automatic scans, single or repeat may be made of a cell program of up to 4, 6 or 8 cells. A programmed sequence of scans may also be made of a single sample.
Time Course Plots
Changing samples or flows may be examined and displayed by making a time course plot. Data may be reprocessed and stored, security code protected, with an automatically assigned recall number.
Sampling
Cells and Flowcells
As well as 10mm cells and flowcells, holders are available for rectangular and cylindrical cells up to 100mm pathlength. A microsampling system measures to 50µl or below. Third party nano cells may also be used.
Turbid Sample Measurements
A turbid sample optical system enables the measurement of heavily scattering samples, which would otherwise be difficult or impossible to measure. 10mm cells, films or solid samples may be measured.
Automatic Cell Changers
Automatic changers are available for 4, 6 or 8 cells, providing rapid sample changing or the facility for full programming.
Sipette Sampling
Samples down to 300 microlitres may be measured in a 10mm cell. Sampling is under control of the instrument's microprocessor system. Samples may be saved or pumped to waste.
Sample Temperature Control
Water and thermoelectric temperature control are available for single cells and automatic cell changers. Temperature is set from the control panel and displayed on the screen.
Batch Sampling
Automatic batch sampling for up to 100 samples is available. The pump fits within the sample compartment and volume etc is set from the control panel and displayed on screen. Batch number entry is provided.
Dissolution Testing
Versions of the instruments fitted with a special cell compartment with piping port, are available for dissolution testing using Cecil TD software and a PC. Six and eight cell changers are available.
Specular Reflectance
Special accessories enable specular reflectance measurements to be made. Both fixed angle and variable angle reflectance accessories are available. The latter is particularly useful for film thickness measurements.
Fluorescence and Gel Scanning
Using the fluorescence accessory quantitative assays are possible. When required the excitation wavelength may be scanned. A gel scanner enables 100mm gels and films to be measured.
================================================
雙光束光學(xué)系統(tǒng)
完全對(duì)稱的光學(xué)系統(tǒng)可以同時(shí)測(cè)量樣品和參比的最終準(zhǔn)確度,精密度和基線平直度。長(zhǎng)期穩(wěn)定性比單波束系統(tǒng)更好的至少10倍。鍍膜光學(xué),使用壽命長(zhǎng)。
可變光帶寬
該CE 9500提供了可變的光帶寬從0.5mm到4毫米。這個(gè)范圍涵蓋了所有的更加嚴(yán)格的應(yīng)用場(chǎng)合是必需的或高光學(xué)分辨率或最高能量的吞吐量。
方法操作和儲(chǔ)存
高達(dá)100套的儀器參數(shù),包括濃度曲線可以存儲(chǔ),安全代碼的保護(hù)。當(dāng)回憶說(shuō),儀器參數(shù)都自動(dòng)設(shè)置,避免錯(cuò)誤。
字母數(shù)字輸入和分析程序
一個(gè)完整的字母數(shù)字設(shè)備提供了一種用于GLP公式輸入和文檔。試驗(yàn)配方條目與測(cè)定程序是快速和使用多個(gè)波長(zhǎng)的計(jì)算可以由高速用完整的文檔的結(jié)果。
軟件增強(qiáng)通過(guò)E- SEF
E- SEF - 編碼軟件增強(qiáng)基金 - 允許使用通過(guò)電話,傳真或電子郵件提供的編碼數(shù)字被激活的軟件模塊。軟件要求可定制的,在任何時(shí)候,根據(jù)需要。
數(shù)據(jù)存儲(chǔ)和保護(hù)
數(shù)據(jù),其中包括100光譜,濃度曲線,動(dòng)力學(xué)和時(shí)間進(jìn)程曲線可以存儲(chǔ)在安全的存儲(chǔ),使用一個(gè)四位數(shù)的密碼安全密碼保護(hù),防止篡改或刪除。
后處理
掃描,時(shí)間過(guò)程圖,并反應(yīng)曲線可以全部進(jìn)行再加工,以在顯示屏幕上的任何所需的格式,然后繪制在積分或外部打印機(jī)。
光電倍增管檢測(cè)器
高性能端窗光電倍增管是用在為最佳的精確度和最佳的性能在窄帶寬,或能量受限的應(yīng)用,如渾濁樣品測(cè)量所有儀器。
性能驗(yàn)證
軟件和認(rèn)證標(biāo)準(zhǔn),使波長(zhǎng)準(zhǔn)確度,吸光度精度,帶寬等進(jìn)行驗(yàn)證。一個(gè)定時(shí)及于報(bào)告包括儀器的序列號(hào)。
強(qiáng)大的定量
許多定量方法可供選擇,包括帶面積計(jì)算與背景校正,差分和光譜,酒和彩色分析,幾個(gè)波長(zhǎng),蛋白質(zhì)和DNA檢測(cè)的數(shù)學(xué)計(jì)算的剝離。
試驗(yàn)計(jì)劃
試驗(yàn)配方需要測(cè)量高達(dá)10個(gè)波長(zhǎng)可以迅速進(jìn)入。編程計(jì)算是自動(dòng)的,無(wú)需用戶干預(yù)項(xiàng)目。自動(dòng)序列可用于多樣品分析和設(shè)置可被存儲(chǔ)為方法。
曲線和擬合線
直線,二次或三次濃度曲線可裝配到高達(dá)30標(biāo)準(zhǔn),使用或不使用截距在原點(diǎn)。標(biāo)準(zhǔn)可能會(huì)被刪除并替換和新的曲線擬合。
反應(yīng)動(dòng)力學(xué)
單細(xì)胞動(dòng)力學(xué)測(cè)量是可能的情節(jié)和畫(huà)面上顯示的數(shù)據(jù)。數(shù)據(jù)可能會(huì)被重新處理,回歸分析應(yīng)用和曲線存儲(chǔ),安全代碼保護(hù),防止篡改或刪除。
多細(xì)胞反應(yīng)動(dòng)力學(xué)
多達(dá)四個(gè)或六個(gè)細(xì)胞與屏幕上顯示的所有反應(yīng)曲線自動(dòng)測(cè)量。每條曲線可用于處理被選擇與回歸分析印刷的結(jié)果。
多波長(zhǎng)及生物測(cè)定
使用兩個(gè)或三個(gè)波長(zhǎng)的光被提供的檢測(cè)。提供一個(gè)葡萄酒的顏色檢測(cè)。用于檢測(cè)華寶和基督教,洛瑞,布拉德福德,縮二脲和BCA方法也可提供。
帶面積和高度計(jì)算
與校正傾斜的背景吸收帶區(qū)域容易量化,并顯示所有的細(xì)節(jié)和建設(shè)。帶區(qū)域也可以被計(jì)算為微分光譜,以便難以定量。
細(xì)胞程序
使用各種細(xì)胞變換器,測(cè)量可以由多達(dá)4或6或8個(gè)細(xì)胞在含有周期時(shí)間和由操作者輸入的周期數(shù)的單一波長(zhǎng)。的細(xì)胞和波長(zhǎng)程序可被組合。
波長(zhǎng)程序
測(cè)量可以被編程為10個(gè)不同的操作員所選擇的波長(zhǎng)的周期時(shí)間和由操作者選定的周期數(shù)。波長(zhǎng)和細(xì)胞程序可被組合。
掃描
雙光束波長(zhǎng)掃描
掃描速度高達(dá)4000nm/min呈現(xiàn)在屏幕上或印有注釋的波長(zhǎng)和吸光度所有峰。表中還提出,列出所有的波峰和波谷與價(jià)值觀。
滾動(dòng)顯示
使用顯示滾動(dòng)設(shè)施的提高有效屏幕尺寸,使光譜和數(shù)據(jù)高達(dá)550毫米寬, 6屏幕的寬度,來(lái)看待。八強(qiáng)掃描通過(guò)輸入其掃描順序號(hào)自動(dòng)保留和召回可能被再加工,重疊或轉(zhuǎn)移到受保護(hù)的內(nèi)存以備將來(lái)調(diào)用。
重疊光譜掃描
多達(dá)六個(gè)的掃描,包括存儲(chǔ)的掃描,也可以重疊,帶或不帶偏移量為便于比較,或進(jìn)一步的操作。
差譜
從存儲(chǔ)新的波長(zhǎng)掃描或掃描可以被呈現(xiàn)在屏幕上,所產(chǎn)生的差示光譜。該掃描可以被歸一化使得頻譜剝露出的雜質(zhì)或添加劑。
導(dǎo)數(shù)光譜
微分光譜,最多第六易于生產(chǎn)的,具有可選的平滑處理,無(wú)論是單獨(dú)或疊加在基本的,帶或不帶偏移量。縮放是自動(dòng)與量化所有的波峰和波谷。
掃描存儲(chǔ)
高達(dá)100光譜可以存儲(chǔ)在10安全存儲(chǔ)銀行以備將來(lái)調(diào)用。每個(gè)光譜是自動(dòng)分配的召回?cái)?shù),存儲(chǔ)時(shí),也可以安全碼保護(hù),以防止篡改或刪除。
編程掃描
自動(dòng)掃描,單次或重復(fù)可以由一個(gè)單元程序的最多4個(gè), 6個(gè)或8個(gè)細(xì)胞。掃描的編排順序也可以由一個(gè)單一的樣本。
時(shí)間課程地塊
更換樣品或流量可檢測(cè)并顯示通過(guò)做一個(gè)時(shí)間過(guò)程的情節(jié)。數(shù)據(jù)可能會(huì)重新處理和存儲(chǔ),安全代碼保護(hù)自動(dòng)分配的召回?cái)?shù)量。
采樣
細(xì)胞和測(cè)量管
以及10毫米細(xì)胞和測(cè)量管,支架可用于矩形和圓柱形電池可達(dá)100mm光程。一個(gè)微量進(jìn)系統(tǒng)的措施, 50μL或以下。第三方納米細(xì)胞也可使用。
渾濁的樣品測(cè)量
混濁樣品光學(xué)系統(tǒng)使大量散射樣品,否則會(huì)難以或無(wú)法測(cè)量的測(cè)量。 10毫米細(xì)胞,膜或固體樣品可以進(jìn)行測(cè)量。
自動(dòng)換電池
自動(dòng)換可用于4,6或8個(gè)細(xì)胞,提供快速樣品更換或設(shè)施進(jìn)行全面編程。
Sipette采樣
樣品下降到300微升可以以10mm比色皿進(jìn)行測(cè)定。抽樣是根據(jù)儀器的微處理器系統(tǒng)的控制權(quán)。樣品可以保存或抽浪費(fèi)。
樣品溫度控制
水和熱電溫度控制可用于單個(gè)細(xì)胞和細(xì)胞自動(dòng)換。溫度從控制面板中設(shè)置和顯示在屏幕上。
批量采樣
自動(dòng)批量采樣多達(dá)100個(gè)樣品是可用的。樣品室中的泵適合,體積等從控制面板中設(shè)置并在屏幕上顯示出來(lái)。提供批號(hào)條目。
溶出度測(cè)試
配有特殊的細(xì)胞室與配管口的工具版本,可使用塞西爾TD軟件和PC溶出度測(cè)試。六到八個(gè)細(xì)胞兌換服務(wù)。
鏡面反射
特殊配件使鏡面反射率測(cè)量作出。兩個(gè)固定角度和變角反射附件可供選擇。后者是用于薄膜厚度測(cè)量時(shí)特別有用。
熒光和凝膠掃描
使用熒光附件的定量分析是可能的。當(dāng)需要的激發(fā)波長(zhǎng)可以被掃描。凝膠掃描儀能夠百毫米凝膠和薄膜進(jìn)行測(cè)量。